Test Code Ovarian Ab Ovarian Antibody Test

Clinical System Name

Ovarian Antibody Test


None specified

Sample Requirements

Specimen: Whole Blood

Container(s): Gold SST or Red

Preferred Vol: 2 mL

Minimum Vol: 0.6 mL

Processing Instructions

Reject due to: Grossly lipemic grossly hemolyzed samples are unacceptable.

Spin: Y

Aliquot: Y

Temp: 2 - 4 C

Storage location: Spin sample and transfer serum into plastic aliquot tube. Store sample in CPA refrigerator send-outs rack.


Off-site collection: Spin sample and transfer serum into plastic aliquot tube. Transport specimen refrigerated.


Specimen Type Temperature Time
Serum Room temp 7 d
  Refrigerated 14 d
  Frozen  30 d



STAT Performed TAT
N Drawn daily; Set-up W at Quest. 4 - 8 d


Performing Laboratory


Quest Diagnostics - Nichols Institute

33608 Ortega Highway
San Juan Capistrano, CA 92690-6130


Phone Number: (800) 553-5445


Department:  Send Outs


Phone Number: (206) 987-2563


Reference Range

Ovarian Antibody Screen: Negative


Ovarian antibody screen is at 1:5 dilution


Method: Immunofluorescent Assay

Analytical Volume: 0.3 mL serum


CPT Codes


If Ovarian Antibody Screen is positive, a titer will be performed at an additional charge (CPT code(s): 86256).

Send Out Instructions


Reference Test Name:

Ovarian Antibody Screen with Reflex to Titer, IFA (10328X)

Reference Test Number:



Send out M - F with the Quest courier.