Sign in →

Test Code LAB174 Immunofixation Electrophoresis

Additional Codes

IMMUNFIX B

Clinical System Name

Immunofixation Electrophoresis

Synonyms

IFIX; Immunoelectrophoresis; Monoclonal Antibody


 

Sample Requirements

Specimen: Whole Blood

Container(s): Gold SST, Red, or Gold Microtainer

Preferred Vol: 2.0 mL

Minimum Vol: 0.6 mL

 

Note: See "Immunofixation, Urine (LAB1953)" for Urine samples. For CSF samples, order a Miscellaneous and send 2.0 mL CSF, refrigerated.

Processing Instructions

Reject due to: 

Spin: Y

Aliquot: Y

Temp: 2 - 4 C

Storage location: Spin sample and transfer serum to plastic aliquot tube. Refrigerate sample in the CPA refrigerator, Send Outs rack.

 

Off-site collection: Spin, aliquot, and transport specimen refrigerated.

Stability

Specimen Type Temperature Time
Serum Room Temp

Unacceptable

  Refrigerated  
  Frozen

 

 

Availability

STAT Performed TAT
N

M - F

 4 d

 

Performing Laboratory

University of Washington Medical Center

Department of Laboratory Medicine

Immunology Lab

1959 NE Pacific St, NW220
Seattle, WA 98195
 

Phone Number: (206) 520-4600

Department

Department: Send Outs

Phone Number: (206) 987-2563

 

 

CPT Codes

86334 (x2)

Methodology

Method: Immunfixation (IFIX)

Analytical Volume: 0.3 mL Serum

Limitations:

Reference Range

Female Male
Age Range Age Range
0- No monoclonal component observed (NOMCO) 0- No monoclonal component observed (NOMCO)

 

Send Out Instructions

Reference Test Name:

Immunofixation

Reference Lab Test Code:

IFIX

Instructions:

Send Monday through Friday with the UW courier.