Test Code LAB1876 Blood Bank Hold, Extra Tube
Clinical System Name
Blood Bank Hold, Extra Tube
Synonyms
Hold Blood Bank Sample
Type and Hold (will NOT be typed, just held)
BB Hold
Sample Requirements
Specimen: Whole Blood
Container(s): Lavender/EDTA
Preferred Vol: 3 mL
Infants <4 months: Minimum 2-3 microtainers each with 0.5 mL
>4 months: Minimum 3 mL
Note: Also accepted - 5-6 full microtainers for patients >4 months if 1 full 3 mL EDTA tube cannot be drawn. For extra tubes, the date is not pre-printed on the generic patient label and must be added. All tubes for a single specimen must have the same date/time and set of initials as the printed Transfusion specimen label.
Note: Samples with extremely low volumes may preclude full ABO typing and may require re-draw if blood product transfusion is required.
Note: Patient arm band, label on specimen, and information in EHR must match including patient LEGAL name, medical record number, and date drawn. Document specimen draw time on filled labeled tube. Perform a 2-person verification at the bedside; both individuals must initial the tube, and the verifier’s name must be entered into the EHR. Deliver specimen to the Lab/Transfusion Service. Refer to Job Aid: Transfusion Specimen Collection, 13143 for more details.
Label Example:
Processing Instructions
Reject due to:
Spin: N
Aliquot: N
Temp: RT
Storage location: Deliver labels and specimen to Transfusion Service.
Off-site collection:
Stability
Specimen Type | Temperature | Time |
---|---|---|
Whole blood | Room temp | |
Refrigerated | ||
Frozen |
Availability
STAT | Performed | TAT |
---|---|---|
Daily | 4 hours from the time of add on testing request | |
Performing Laboratory
Seattle Children's Laboratory
Department
Department: Transfusion Service
Phone Number: (206) 987-5151
Methodology
Method: None specified
Analytical Volume: None specified
Limitations:
Reference Range
None specified
Requisition
Downtime: Request for Testing and Blood Components