Sign in →

Test Code LAB1970 Urine Bicarbonate

Additional Codes

HCO3 U

Clinical System Name

Urine Bicarbonate

Synonyms

Bicarbonate (HCO3) Urine
HCO3, Urine
Urine Bicarbonate
Urine HCO3

 

Sample Requirements

Specimen: Urine

Container(s): Syringe, Red, Dark Green/Sodium Heparin

Preferred Vol: See Note

Minimum Vol: 0.2 mL

Note: Specimen requirements: 1.0 - 10.0 mL random urine collected anaerobically in a syringe. Seal syringe and place on ice. Do not expose sample to air. Send to the lab immediately. Refer to Clinical Policy/Procedures for "Urine Specimen from an Indwelling Catheter" for specimen collection information. Urine collected in a cup may also be transfered to a Red Top Tube.

Processing Instructions

Reject due to: Lavender/EDTA

Spin: N

Aliquot: N

Temp: 2 - 4 C

Storage Location: Minimize exposure to air. Give promptly to Send Outs. If Send Outs is unavailable, follow the STAT Send Outs Procedure by batching the test in MayoACCESS. Send the sample STAT on an ice pack to the UWMC Room NW220 via DIRECT Delivery Express.

 

Off-site Collection: No off-site collections.

Stability

Specimen Type Temperature Time
  Room temp

1 h

  Refrigerated  
  Frozen

 

 

Availability

STAT Performed TAT
Y Daily 5 h

 

Performing Laboratory

UW Medical Center

Chemistry

1959 NE Pacific street, Room NW220
Seattle, WA 98195

 

Phone Number: (206) 520-4600

For STAT Inquiries, refer to Phone Number: (206) 744-3451

Department

Department: Send Outs

Phone Number: (206) 987-2563

Methodology

Method: Spectrophotometric

Analytical Volume: Not indicated.

Limitations:

Reference Range

<5 mEq/L

CPT Codes

82374

Send Out Instructions

Reference Test Name: Carbon Dioxide, Fluid
Reference Lab Test Code:

FCO2G

Instructions:

Send STAT to UWMC room NW220 on an ice pack via DIRECT Delivery Express.