Test Code LAB2859 C1 Esterase Inhib Protein+Func
Additional Codes
C1ESTER GR
Clinical System Name
C1 Esterase Inhib Protein+Func
Synonyms
C1 Esterase Inhibitor Activity; C1 Esterase Inhib Func - Quant; C1 Esterase Inhibitor; C1 Esterase Inhibitor Function - Quant; C1 Inactivator; C1 Inhibitor
Sample Requirements
Specimen: Whole Blood
Container(s): Gold SST, Red, or Gold Microtainer
Preferred Vol: 3.0 mL
Minimum Vol: 2.0 mL
Note: Send to the main laboratory STAT. Must be frozen within ONE hour of collection. Panel includes both "functional" and "protein."
Processing Instructions
Reject due to:
Spin: Y
Aliquot: Y
Temp: -70 C
Storage Location: Serum must be frozen within ONE hour of collection. Spin whole blood and freeze 1.0 mL serum, split between two separate aliquot tubes (two 0.5 mL aliquots). Affix each aliquot with a large Cerner label. Freeze in the -70 C freezer Send Outs rack.
Off-site Collection: Spin whole blood, freeze 1.0 mL serum split between two separate aliquot tubes (two 0.5 mL aliquots); each affixed with a large Cerner label. Freeze at -70 C.
Stability
Specimen Type | Temperature | Time |
---|---|---|
Room Temp | N | |
Refrigerated | N | |
Frozen | 2 w |
Availability
STAT | Performed | TAT |
---|---|---|
N | Th | 3 - 14 d |
Performing Laboratory
University of Washington Medical Center
Department of Laboratory Medicine
1959 NE Pacific St, NW220
Seattle, WA 98195
Phone Number: (206) 520-4600
Department
Department: Send Outs
Phone Number: (206) 987-2563
CPT Codes
86160, 86161
Methodology
Method: ELISA
Analytical Volume: 0.5 mL Serum in each aliquot
Limitations:
Reference Range
Protein Level | Functional | |
20 - 40 mG/dL | Normal Function | > 68% |
Equivocal | 41 - 68 % | |
Decreased Function | < 40% |
Send Out Instructions
Reference Test Name: | C1 Esterase Inhibitor Panel |
Reference Test Number: | C1EP |
Instructions: | Send out Monday through Friday with the UW courier. |