Sign in →

Test Code LAB3247 Lepidoglyphus destructor, IgE, Serum

Additional Codes

LepDes IgE

Reporting Name

Lepidoglyphus Destructor, IgE
Seattle Children's Hospital Note:

SCH Clinical System Name: Lepidoglyphus destructor, IgE

Useful For

Establishing a diagnosis of an allergy to Lepidoglyphus destructor

 

Defining the allergen responsible for eliciting signs and symptoms

 

Identifying allergens:

-Responsible for allergic response and/or anaphylactic episode

-To confirm sensitization prior to beginning immunotherapy

-To investigate the specificity of allergic reactions to insect venom allergens, drugs, or chemical allergens

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Serum


Ordering Guidance


For a listing of allergens available for testing, see Allergens - Immunoglobulin E (IgE) Antibodies.



Specimen Required


Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL for every 5 allergens requested

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Specimen Minimum Volume

For 1 allergen: 0.3 mL
For more than 1 allergen: (0.05 mL x number of allergens) + 0.25 mL deadspace

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 14 days
  Frozen  90 days

Reference Values

Class

IgE kU/L

Interpretation

0

<0.10

Negative

0/1

0.10-0.34

Borderline/equivocal

1

0.35-0.69

Equivocal

2

0.70-3.49

Positive

3

3.50-17.4

Positive

4

17.5-49.9

Strongly positive

5

50.0-99.9

Strongly positive

6

≥100

Strongly positive

 

Reference values apply to all ages.

Day(s) Performed

Monday through Friday

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

86003

LOINC Code Information

Test ID Test Order Name Order LOINC Value
LEPD Lepidoglyphus Destructor, IgE 6160-6

 

Result ID Test Result Name Result LOINC Value
LEPD Lepidoglyphus Destructor, IgE 6160-6

Method Description

Specific IgE from the patient's serum reacts with the allergen of interest, which is covalently coupled to an ImmunoCAP. After washing away nonspecific IgE, enzyme-labeled anti-IgE antibody is added to form a complex. After incubation, unbound anti-IgE is washed away, and the bound complex incubated with a developing agent. After stopping the reaction, the fluorescence of the eluate is measured. Fluorescence is proportional to the amount of specific IgE present in the patient's sample (ie, the higher the fluorescence value, the more IgE antibody is present).(Package insert: ImmunoCAP System Specific IgE FEIA. Phadia; Rev 06/2020)

Report Available

Same day/1 to 3 days

Reject Due To

Gross hemolysis OK
Gross lipemia OK

Method Name

Fluorescence Enzyme Immunoassay (FEIA)

Forms

If not ordering electronically, complete, print, and send an Allergen Test Request (T236) with the specimen.

Seattle Children's Hospital Additional Information:

Aliases: House dust mite, Lepidoglyphus dust; Storage Mite