Test Code LAB3458 Soluble C5b-9 Assay
Clinical System Name
Soluble C5b-9 Assay
Synonyms
MAC (SC5b-9)
Eculizumab Monitor (SC5b-9)
Membrane Attack Complex (SC5b-9)
Soluble Terminal Complement Complex (SC5b-9)
Sample Requirements
Specimen: Whole Blood
Container(s): Lavender/EDTA
Preferred Vol: 1.5 mL
Minimum Vol: 1.0 mL
Note: Deliver to lab immediately.
Processing Instructions
Reject due to: Incorrect anticoagulant. Hemolyzed, clotted, or older than 2 hours unspun.
Spin: Y
Aliquot: Y
Temp: -20 C
Storage Location: Separate plasma from cells within TWO hours of collection. Spin bood and transfer 0.5 mL plasma (Min. 0.2 mL) to an aliquot tube affixed with large Epic label. Place sample in the CPA freezer Fz3 rack.
Off-site Collection: Separate plasma from cells within TWO hours of collection. Spin bood and transfer 0.5 mL plasma (Min. 0.2 mL) to an aliquot tube affixed with large Epic label. Freeze at -20 C. Transport frozen.
Stability
Specimen Type | Temperature | Time |
---|---|---|
Whole Blood | RT | 2 h |
2-8 C | 2 h | |
Plasma | RT | 8 h |
2-8 C | 24 h | |
-20 C | 6 m |
Availability
Samples in lab by 0900 Monday will be resulted by 1800 Monday.
Contact Chemistry Department (206-987-2565, LabChemistry@seattlechildrens.org) by 1500 Wednesday for approval to set-up an additional Thursday run.
STAT | Performed | TAT |
---|---|---|
N | M | 7 d |
Note: If Monday is a holiday, then the run may be set-up on Monday or Wednesday.
Performing Laboratory
Seattle Children's Laboratory
Department
Department: Chemistry
Phone Number: (206) 987-2617
CPT Codes
86160
Methodology
Method: EIA on the DS2
Analytical Volume: 0.2 mL Plasma
Limitations:
Reference Range
< 250 ng/mL