Test Code LAB3493 Thermal Amplitude

Additional Codes

ThermAmp

Clinical System Name

Thermal Amplitude

 

Sample Requirements

Specimen: Whole Blood

Container(s): Lavender/EDTA or Red (Not Preferred)

Preferred Vol: 7.0 mL

Minimum Vol: 7.0 mL

 

*Pediatric Minimum Vol: 1 full 3.0 mL Lavender/EDTA tube

*Neonate Minimum Vol: 2 full 0.5 mL Lavender/EDTA microtainers

 

Note: NO GEL SEPARATORS. Please call the Immunohematology Reference Laboratory at (206) 689-6525 prior to collecting sample. Complete a BWNW Compatibility Testing Laboratory RFT. A red top is acceptable though not preferred. SAMPLE MUST BE KEPT AT BODY TEMPERATURE AT ALL TIMES. After collection, immediately place tube in an activated disposable infant heel warmer. Send the specimen and the completed requisition to the lab IMMEDIATELY.

 

Processing Instructions

Reject due to: Gold/SST, Serum separator gel tube

Spin: Y

Aliquot: Y

Temp: RT

Storage location: PROCESS SAMPLE IMMEDIATELY. Sample must be kept at 37 C at all times. Spin blood, transfer plasma/serum into a plastic aliquot tube labeled with a large Epic label, and place in the room temperature Send Outs rack. Notify Send Outs wet bench personnel or the Send Outs department. Use BWNW Compatibility Testing Laboratory RFT. Fill out as completely as possible. Place a large Epic label in the top right corner.

Availability

STAT Performed TAT
N Daily 1 - 3 d

 

Performing Laboratory

Bloodworks Northwest

Immunohematology Reference Laboratory

921 Terry Avenue

Seattle, WA 98104

 

Phone: (206) 689-6252

Department

Department: Send Outs

Phone: (206) 987-2563

CPT Codes

86940 (x3), 86941 (x3)

Methodology

Method: Hemagglutination

Analytical Volume: None specified

Limitations:

Reference Range

Interpretive report provided.

Send Out Instructions

Reference Test Name: Thermal Amplitude
Reference Lab Test Code: 3140-00
Instructions: Place sample and completed requisition in the Send Outs room temperature rack.