Sign in →

Test Code LAB3597 BWNW DONOR Virology Battery

Additional Codes

DONOR VIR

Clinical System Name

BWNW DONOR Virology Battery

Synonyms

BWNW Donor Virology Battery; Donor Battery; Donor Virology Battery; Virology Donor Panel

 

Sample Requirements

Specimen: Whole Blood

Container(s): Red AND Lavender/EDTA

Preferred Vol: 7.0 mL Red + 14.0 mL (2 x 7.0 mL) Lavender/EDTA

Minimum Vol: 6.0 mL Red + 12.0 mL (2 x 6.0 mL) Lavender/EDTA

 

Note: Donor Battery includes: HBsAg, anti-HBc, anti-HCV, anti-HTLV-I/II, anti-HIV-1/HIV-2, and STS, anti-T. cruzi, cobas™ MPX (HCV/HIV/HBV)/WNV NAT. EDTA solution can be K2 or K3, not Na2. Write date and time on patient label. Use BWNW Donor Testing Laboratory RFT. Deliver whole blood to the Main Lab.

 

Processing Instructions

Reject due to:

Spin: N

Aliquot: N

Temp: RT

Storage Location: Give whole blood to Send Outs with BWNW Donor Testing Laboratory RFT. The requisition must be complete and accompany specimen to lab. Place the bagged specimen, requisition, and labels in the room temperature Send Outs bin.

 

Off-site collection:

Stability

Specimen Type Temperature Time
Whole Blood Room temp 5 d
  Refrigerated 5 d
  Frozen Unacceptable

Availability

STAT Performed TAT
N Daily 3 d

 

Performing Laboratory

Bloodworks Northwest

Donor Testing/Virology Lab

921 Terry Avenue

Seattle WA 98104

 

Phone Number: (425) 656-7907

Department

Department: Send Outs

Phone Number: (206) 987-2563

 

Methodology

Method: None specified

Analytical Volume: 6.0 mL - 7.0 mL Red and TWO 6.0 mL - 7.0 mL Lavender/EDTA

Limitations:

Reference Range

Nonreactive

Send Out Instructions

Reference Test Name:

Donor Battery

Reference Lab Test Code:  
Instructions: Send sample and requisition to BWNW via courier.

 

Description

Donor Battery includes: HBsAg, anti-HBc, anti-HCV, anti-HTLV-I/II, anti-HIV-1/HIV-2, and STS, anti-T. cruzi, cobas™ MPX (HCV/HIV/HBV)/WNV NAT.