Test Code LAB3724 Anti-Xa for Apixaban Level
Description
The ability of patient plasma to inhibit a chromogenic assay for activated factor X is measured. The apixaban concentration is determined by comparing the inhibition of factor Xa by patient plasma to a calibration curve generated using known concentrations of apixaban.
Clinical System Name
Anti-Xa for Apixaban Level
Synonyms
Anti 10A; Anti Factor X; AntiX; Apixan; Eliquis; Factor 10A; anti factor 10; anti-factor 10; anti-factor X; antiXa
Sample Requirements
Specimen: Whole Blood
Container(s): Lt. Blue/Citrate
Preferred Vol: (3) 1.8 mL or (1) 2.7 mL
Minimum Vol: (2) 1.8 mL
Note: Preferred method of collection is venipuncture with vacuum fill. Test results are affected by incorrect blood volume. Use of a Vascular Access Device for the collection of coag testing is not recommended.
If this method is used it requires a 5 cc clearing volume; 3 cc for size 2 French catheter or smaller. Blood must be trasferred to the Lt Blue/Citrate tube by use of a blood transfer device to ensure proper fill.
Specimen should be centrifuged within ONE hour of collection.
Processing Instructions
Reject due to: Clotted, hemolyzed, insufficient quantity, or improper collection.
Spin: Y
Aliquot: Y
Temp: -70 C
Storage Location: Core 6 Freezer (-70 C) Send Outs rack.
Note: Deliver blood to Core Coag bench. Coag Technologist will process. Specimen should be centrifuged within ONE hour of collection. Spin whole blood, remove plasma. Transfer upper 3/4 layer of plasma to plastic tube and make two aliquots of 0.6 mL, affix large Cerner label and store in -70 freezer, Send Out rack.
Off-site Collection: Preferred method of collection is venipuncture with vacuum fill. Test results are affected by incorrect blood volume. Use of a Vascular Access Device for the collection of coag testing is not recommended. If this method is used it requires a 5 cc clearing volume; 3 cc for size 2 French catheter or smaller. Blood must be trasferred to the Lt Blue/Citrate tube by use of the blood transfer device.
Specimen should be centrifuged within ONE hour of collection. Double spin, transfer upper 3/4 layer of plasma to plastic tube affixed with large computer label. Freeze 2 aliquots of 0.6 mL plasma in plastic tubes at -70C. Ship frozen on dry ice.
Stability
Specimen Type | Temperature | Time |
Citrated Platelet-Poor Plasma | Room Temp | N |
Refrigerated | N | |
Frozen | Y |
Availability
STAT | Performed | TAT |
Y, w/Approval | Daily | 1 d |
Performing Laboratory
University of Washington Medical Center
Clinical Coagulation Lab
1959 NE Pacific Street
Room NW220
Seattle, WA 98195
Phone Number: (206) 520-4600
Department
Department: Send Outs
Phone Number: (206) 987-2563
CPT Codes
80299
Reference Ranges
See individual components.
Methodology
Method: Chromogenic
Analytical Volume: 0.5 mL Citrate Plasma
Limitations:
Send Out Instructions
Reference Test Name: | Anti-Xa for Apixaban Level |
Reference Test Code: | APIXN1 |
Instructions: | Send out Monday through Friday with the UW courier. |