Test Code LAB3767 Meropenem Level

Clinical System Name

Meropenem Level

Sample Requirements

Specimen: Whole Blood

Container(s): Red Top - Plain

Preferred Vol: 3.0 mL

Minimum Vol: 2.0 mL

 

Note: Gold SST is unacceptable for this testing. This test requires collection in a Red Top - Plain tube.

Processing Instructions

Reject due to: Gold SST

Spin: Y

Aliquot: Y

Temp: -20 C

Storage Location: CPA -20 Freezer, Send Outs rack.

 

Off-site Collection: Spin, aliquot, and freeze at -20 C. Transport frozen.

Stability

Specimen Type Temperature Time
Serum Room Temp Unacceptable
  Refrigerated 8 h
  Frozen 1 m

 

Availability

STAT Performed TAT
Y Daily 48 h

 

Performing Laboratory

Atlantic Diagnostic Laboratories, LLC

3520 Progress Drive, Suite C

Bensalem, PA 19020

 

Phone Number: (267) 525-2470

Department

Department: Send Outs

Phone Number: (206) 987-2563

CPT Codes

80299

Methodology

Method:

Analytical Volume: 1.0 mL Serum

Limitations:

Send Out Instructions

Reference Test Name: Meropenem
Reference Test Code: 6996
Instructions: Send out Monday - Friday via FedEx Priority Overnight. Atlantic Diagnostic Laboratories accepts Saturday deliveries.