Test Code LAB3913 Rupture of Fetal Membranes
Additional Codes
Rupture of Fetal Membranes
Sample Requirements
Specimen: Qiagen vaginal swab in buffer
Container(s): Vaginal swab from Qiagen AmniSure kit only (kits provided by UW Lab Medicine, call 206-668-1344 for info).
Note: The specimen should be obtained by carefully inserting the polyester tip of the swab into the vagina approximately 2 to 3 inches deep for 1 full minute. After 1 minute, the swab should be removed and placed into the Qiagen AmniSure solvent vial and rinsed by rotation for 1 full minute. After 1 minute, the swab can be disposed of. The labeled solvent vial should then be sent to the laboratory.
Processing Instructions
Reject due to:
Spin: N
Aliquot: N
Temp: 2 - 8 C
Storage Location: Place sample in CPA refrigerator, Send Outs rack. Please notify the Send Outs department ASAP.
Performing Laboratory
Northwest Hospital - Chemistry
1550 N 115th Street, A200
Seattle, WA 98133
1550 N 115th St, A-200
Seattle, WA 98133
Phone: (206) 668-1344
Department
Department: Send Outs
Phone Number: (206) 987-2563
Synonyms
AmniSure
Fern
Ferning
ROM
Rupture of Membranes
Availability
STAT | Performed | TAT |
---|---|---|
Y | Daily | 1 d |
Methodology
Method: Immunochromatographic
Limitations: 24-hour Stability (do not reject - please escalate)
CPT Codes
84112
Send Out Instructions
Reference Test Name: |
Rupture of Fetal Membranes |
Reference Lab Test Code: | ROMNW |
Instructions: |
Send samples via DIRECT Delivery Express courier to Northwest Hospital. |