Sign in →

Test Code LAB973 B-12 Binding Capacity

Additional Codes

VIT B12 BC

Clinical System Name

B-12 Binding Capacity

Synonyms

B12, B12B; Transcobalamin

Sample Requirements

Specimen: Blood

Container(s): Red Top-Plain

Preferred Vol: 2.0 mL

Minimum Vol: 1.0 mL

 

Note: Patient should fast for 12-15 hours prior to collection. Vitamin B12 supplements should not be administered within 72 hours of drawing blood for this test.

Processing Instructions

Reject due to: Plasma.

Spin: Y

Aliquot: Y

Temp: 2 - 4 C

Storage Location: CPA refrigerator, Send Outs rack.

 

Off-site collection: Transfer 1.0 mL serum to a plastic aliquot tube (Min: 0.1 mL). Transport refrigerated to Seattle Children's Main Lab.

Stability

Specimen Type Temperature Time
Serum Room Temp 6 h
  Refrigerated 1 w
  Frozen 1 m

 

Availability

STAT Performed TAT
N M, Th 3 - 7 d

 

Performing Laboratory

ARUP Laboratories

500 Chipeta Way

Salt Lake City, UT 84108-1221

 

Phone Number: (800) 522-2787

Department

Department: Send Outs

Phone Number: (206) 987-2563

CPT Codes

82608

Methodology

Method: Quantitative Radioimmunoassay

Analytical Volume: 0.1 mL Serum

Limitations:

Send Out Instructions

Reference Test Name Vitamin B12 Binding Capacity
Reference Lab Test Code 0070260
Instructions Send out Monday through Friday with the ARUP courier.

 

Reference Ranges

800-2600 pg/mL